Configuration and activation
A31003-M2000-M103-2-76A9, 07/2014
3-13 Alarm and Emergency Call Configuration, Administrator Documentation
SHB_PNG-Konfig.fm
Configuration menu
6. Change the values of the following parameters:
7. Confirm with Save.
3.2.1.3 Control Ports
The control ports are phone numbers of the alarm server that are used for signalling the states/
events between the handset and the alarm server.
The phone numbers of the control ports are entered automatically in Alarm Mode and PNG
Mode if the Control Port Basic parameter has been configured in Alarm Mode or PNG Mode.
The control ports can then also be modified individually. The three control ports in Basic Mode
have to be entered individually.
For more information on control ports please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1. Select the Additional Features icon in the main menu.
2. Select Configuration.
3. Enter the five-position service PIN and confirm with OK.
4. Select one of the three operating modes.
5. Select Control Ports.
6. Change the values of the following parameters:
Parameters Operating Mode Value Range Standard Value
Automatic BM/AM/PNG On/off Off
Manual BM/AM/PNG On/off On
Table 3-10 Parameter – [Mode] Activation
>
Basic Mode and Alarm Mode: Alarm Mode can be activated after deleting the Start,
NOK and Stop Availability ports without logging on to the alarm server.
The sensor check required in Alarm Mode is then also not performed.