SHB_PNG-Konfig.fm
A31003-M2000-M103-2-76A9, 07/2014
Alarm and Emergency Call Configuration, Administrator Documentation
3-6
Configuration and activation
Configuration menu
Manual Alarm
You can configure all settings here for the manual alarm, in other words for the alarm triggered
with the red alarm key.
Depending on how the red alarm key is pressed (SP: Shortpress, LP: Longpress), different
alarms are signalled and different alarm destinations are dialled.
For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1. Select the Additional Features icon in the main menu.
2. Select Configuration.
3. Enter the five-position service PIN and confirm with OK.
4. Select one of the three operating modes.
5. Select Alarms.
6. Select Manual Alarm.
7. Change the values of the following parameters:
8. Confirm with Save.
>
The red key is assigned for the manual alarm in Alarm Mode and PNG Mode
following activation. The numbers configured under the emergency call (Section
3.2.2, "Emergency Call") are selected if no mode is active. The emergency number
is overwritten by the alarm server with its own emergency number when the Control
Port Basic parameter is entered.
AM/PNG
Parameters Value Range Standard Value
Alarm Key SP On/off On
Alarm Key LP On/off On
Alarm Key locked On/off Off
Alarm Signal SP On/off On
Alarm Signal LP On/off Off
Alarm Destination SP (up to 32 digits) (blank)
Alarm Destination LP (up to 32 digits) (blank)
Table 3-2 Parameter – Manual Alarm